Turbimax CUS71D
Brand: Endress+HauserTurbimax CUS71D
Brand: Endress+Hauser
Extended Specs at a Glance
Process temperature:
1 to 50 °C (34 to 122 °F)
Process pressure:
Standard version: 0 to 6 bar (0 to 87 psi)
Version with wiper: 0 to 0.3 bar (0 to 4.4 psi)
Version with wiper: 0 to 0.3 bar (0 to 4.4 psi)
Measuring range:
0.3 to 10 m (1 to 32 ft)
Field of application
Turbimax CUS71D continuously monitors the separation and transition zones in clarification and settling tanks, ensuring safe, economic and efficient sedimentation processes. It provides you with reliable, real-time measured values in real-time for quick control of valves and actuators. Turbimax CUS71D is ideal sensor for every measuring task - from protection of downstream water in wastewater treatment plants to optimization of backwash times in waterworks.
Turbimax CUS71D is an online ultrasonic interface sensor for:
- Wastewater treatment plants:- Solid sedimentation measurement
- Drinking and process water:- Solid sedimentation measurement- Filter monitoring and filter backwash- Level measurement in marble chip tanks
- Utilities of all industries:- Static separation processes- Reuse of process water- Product separation- Flotation processes
Key Benefits
- Reliable: Sensor provides accurate and continuous measurement of interface level or range.
- Safe: Real-time interface information ensures quick control of valves and actuators.
- Easy: Simple commissioning thanks to predefined calculation models.
- Cost-saving: Automatic wiper cleaning function enables long-term, maintenance-free operation.
- Intelligent: All calibration and sensor-specific data stored in the sensor.
- Flexible: Mounting hardware suits all clarifier designs for optimal adaption to the measuring task
Specifications
Brand
Industry
- Water, Wastewater & Waste
- Mining, Minerals & Metals
Product Family
- Turbimax
Sludge Level
Application
- Continious interface measurement in sedimentation basins
Installation
- Submerged sensor with fixed cable
Measuring range
- 0.3 to 10 m (1 to 32 ft)
Measuring principle
- Ultrasonic return-time measurement
Material
- Sensor: ABS and epoxy resin
- Wiper: EPDM
- Housing: Polyamide
Dimension
- Diameter: 74 mm(2.9 inch)
- Lenght standard sensor: 68 mm (2.7 inch)
- Lenght wiper sensor: 135 mm (5.3 inch)
Process temperature
- 1 to 50 °C (34 to 122 °F)
Process pressure
- Standard version: 0 to 6 bar (0 to 87 psi)
- Version with wiper: 0 to 0.3 bar (0 to 4.4 psi)
Temperature sensor
- -
Ex certification
- None
Connection
- Process connection: G1 and NPT 3/4"
- Fixed cable 15 m
Ingress protection
- IP68
Output / communication
- Digital output for connection to Liquiline CM44x
Additional certifications
- EAC