Ultrasonic level sensor Prosonic FMU4x FMU41

Brand: Endress+Hauser

Ultrasonic level sensor Prosonic FMU4x FMU41

Brand: Endress+Hauser

Miller Mechanical Specialties, Endress+Hauser's exclusive USA representative in:
IA MN Eastern ND NE SD Parts of WI

Extended Extended

Specs at a Glance

Process pressure / max. overpressure limit:
0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
Main wetted parts:
PVDF
Process temperature:
-40 °C ... 80 °C
(-40 °F ... 176 °F)
Max. measurement distance:
Liquids: 8 m (26 ft),
Solids: 3.5 m (11 ft)
Accuracy:
+/- 2 mm or +/- 0,2 % of set measuring range 1)

Field of application

The Prosonic FMU41 is an ultrasonic level sensor designed for non-contact level measurement of liquids and bulk solids. This versatile device can be used in both two-wire and four-wire systems, making it suitable for sophisticated applications. Utilizing the Time-of-Flight method, it ensures accurate and reliable measurements.

Specifications

Industry

  • Chemical
  • Water, Wastewater & Waste
  • Food & Beverage
  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Pulp & Paper (incl. Printing)

Product Family

  • Prosonic

Continuous / Liquids

Characteristic / Application

  • Compact ultrasonic transmitter

Supply / Communication

  • 2-wire HART

Accuracy

  • +/- 2 mm or +/- 0,2 % of set measuring range

Ambient temperature

  • -40 °C ... 80 °C
  • (-40 °F ... 176 °F)

Process temperature

  • -40 °C ... 80 °C
  • (-40 °F ... 176 °F)

Process pressure / max. overpressure limit

  • 0.7 bar ... 3 bar abs
  • (10 psi ... 44 psi)

Main wetted parts

  • PVDF

Process connection

  • G / NPT 2"

Blocking distance

  • 0.35 m (1.15 ft)

Max. measurement distance

  • Liquids: 8 m (26 ft),
  • Solids: 3.5 m (11 ft)

Communication

  • 4...20 mA HART

Certificates / Approvals

  • ATEX, FM, CSA, IEC, INMETRO, NEPSI

Application limits

  • For higher resistance:
  • FMU42/FDU9x
  • Foam / high turbulence possible:
  • FMU42/FDU91
  • Fast filling and discharging rate:
  • FMU90 + FDU9x
  • Level limit detection:

Continuous / Solids

Characteristic / Application

  • Compact ultrasonic transmitter

Supply / Communication

  • 2-wire HART

Accuracy

  • +/- 2 mm or +/- 0,2 % of set measuring range 1)

Ambient temperature

  • -40 °C ... 80 °C
  • (-40 °F ... 176 °F)

Process temperature

  • -40 °C ... 80 °C
  • (-40 °F ... 176 °F)

Process pressure / max. overpressure limit

  • 0.7 bar ... 3 bar abs
  • (10 psi ... 44 psi)

Main wetted parts

  • PVDF

Process connection

  • G / NPT 2"

Blocking distance

  • 0.35 m (1.15 ft)

Max. measurement distance

  • Liquids: 8 m (26 ft),
  • Solids: 3.5 m (11 ft)

Communication

  • 4...20 mA HART

Certificates / Approvals

  • ATEX, FM, CSA, IEC, INMETRO, NEPSI

Application limits

  • Take notice of range diagram

Liquids

Product headline

  • Compact ultrasonic measuring instrument
  • Cost effective solution for open channels

Max. measurement error

  • > 2 mm depending on flow application

Measuring range

  • Measuring distance 0.4...8 m [1.3...26 ft]

Max. process pressure

  • 0.7 bar...3 bar (10 psi...44 psi)

Medium temperature range

  • -40°C...80°C
  • (-40°F...176°F)

Degree of protection

  • IP68

Outputs

  • 4...20mA HART

Inputs

  • 2-wire

Digital communication

  • HART

Hazardous area approvals

  • ATEX, IEC, FM, CSA, INMETRO, NEPSI
show more