Chlorine Sensors & Transmitters

Products for reliable measurement of chlorine and bromine-based disinfectants.

1 - 25 of 25 Products
Digital Total Chlorine Sensor Memosens CCS53E
Endress+Hauser
Digital total chlorine sensor Memosens CCS53E
Extended Extended
Request Information
Analog Free Chlorine Sensor Memosens CCS51
Endress+Hauser
Analog free chlorine sensor CCS51
Request Information
Digital Service Tool Memocheck CYP02E
Endress+Hauser
Digital service tool Memocheck CYP02E
Request Information
Flow Assembly for Multi-Parameter Measurements Flowfit CYA27
Endress+Hauser
Flow assembly for multi-parameter measurements Flowfit CYA27
Request Information
Digital Chlorine Dioxide Sensor Memosens CCS50E
Endress+Hauser
Digital chlorine dioxide sensor Memosens CCS50E
Extended Extended
Request Information
Zero-Point Gel COY8
Endress+Hauser
Zero_point_gel_COY8_1.png
Request Information
Liquiline Edge Module CYY7
Endress+Hauser
Liquiline Edge Module CYY7
Extended Extended
Request Information
4-Channel Transmitter Liquiline CM444R
Endress+Hauser
CM444R.png
Extended Extended
Request Information
Analog Chlorine Dioxide Sensor Memosens CCS50
Endress+Hauser
Analog chlorine dioxide sensor CCS50
Request Information
8-Channel Transmitter Liquiline CM448R
Endress+Hauser
CM448R.png
Extended Extended
Request Information
Digital Extension Cable Memosens CYK11
Endress+Hauser
Digital extension cable CYK11
Request Information
Digital Free Bromine Sensor Memosens CCS55E
Endress+Hauser
Digital free bromine sensor Memosens CCS55E
Extended Extended
Request Information
Digital Service and Qualification Tool Memocheck Sim CYP03D
Endress+Hauser
Digital service and qualification tool Memocheck Sim CYP03D
Request Information
1-/2-Channel Transmitter Liquiline CM442
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Immersion Assembly Flexdip CYA112
Endress+Hauser
CYA112_Rendering_2.png
Request Information
1-/2-Channel Transmitter Liquiline CM442R
Endress+Hauser
CM442R.png
Extended Extended
Request Information
4-Channel Transmitter Liquiline CM444
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Multichannel Transmitter Liquiline CM44P
Endress+Hauser
Liquiline_CM44P_AU.png
Extended Extended
Request Information
Disinfection Transmitter Liquisys CCM223
Endress+Hauser
Disinfection transmitter Liquisys CCM223
Request Information
8-Channel Transmitter Liquiline CM448
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Digital Ozone Sensor Memosens CCS58E
Endress+Hauser
Digital ozone sensor Memosens CCS58E
Extended Extended
Request Information
Digital Measuring Cable CYK20
Endress+Hauser
CYK20_Memosens cable_nonEx.png
Request Information
Digital Free Chlorine Sensor Memosens CCS51E
Endress+Hauser
Digital free chlorine sensor Memosens CCS51E
Extended Extended
Request Information
Disinfection Transmitter Liquisys CCM253
Endress+Hauser
Disinfection transmitter Liquisys CCM253
Request Information
Digital Measuring Cable Memosens CYK10
Endress+Hauser
Digital measuring cable CYK10
Request Information

Chlorine Sensors & Transmitters

Chlorine sensors and transmitters are analytical measurement systems used to control and document disinfection performance in water and related aqueous processes. The category includes sensors for free chlorine, total chlorine, chlorine dioxide, and free bromine, paired with transmitters and assemblies that condition the sample and provide stable, temperature-compensated signals for control and reporting.

Disinfection control is inherently a balance: insufficient residual can compromise microbiological safety, while excessive disinfectant increases corrosion potential, byproduct formation risk, and chemical cost. Continuous measurement supports regulation-aligned dosing and rapid detection of process deviations, enabling tighter control loops and more consistent residual management across changing flow, temperature, and demand conditions.

Many installations use amperometric measuring principles in which disinfectant species diffuse through a membrane and generate an electrochemical response proportional to concentration. For free chlorine, the speciation dependence on pH is commonly addressed through pH compensation within the measuring point and transmitter logic, improving residual accuracy under variable chemistry. Selection is application-driven: free chlorine for many drinking-water and hygienic applications; chlorine dioxide where pH independence and lower corrosivity are advantageous; total chlorine for residual indication; bromine for seawater-influenced systems.

Mechanical and hydraulic execution is as important as sensor selection. Flow assemblies provide controlled velocity, stable pressure, and proper placement for multi-parameter compensation; basin/channel mounting expands applicability for open systems. Endress+Hauser offerings also extend to pre-engineered disinfection monitoring panels that combine sensor, transmitter, assembly, and accessories into a compact measuring point concept.

Typical applications include drinking-water disinfection residual control, swimming pool dosing optimization, process and reuse water disinfection, cooling systems and towers, wash-water hygiene for packaged foods, desalination pretreatment (including avoiding interference with reverse osmosis), wastewater effluent residual verification, fish farming, and other seawater process streams where bromine-based disinfection is preferred.

Miller Mechanical Specialties, an exclusive authorized representative of sales and service for Endress+Hauser.